Hongrijia Depurate Facility Science & Technology Co., Ltd. yuka@szyuka.cn 86-0755-28686438
Product Details
Place of Origin: China
Brand Name: Yuka
Payment & Shipping Terms
Minimum Order Quantity: 50pcs
Price: Negotiable
Packaging Details: Box Package
Delivery Time: 3-7working days
Payment Terms: L/C,T/T
Supply Ability: 300,000pcs/month
Model No.: |
HFD040 |
Origin: |
China |
HS Code: |
8421399090 |
Clapboard: |
Without Clapboard |
Filter Number: |
1 |
Medium Material: |
Fiberglass |
Type: |
Cartridge Filter |
Material: |
Aluminum Alloy |
Housing Serve Lige: |
15 Years |
Filtration Performance: |
From 5 μm To 0.01μm |
Operate Temperature: |
1.5~80ºc |
Resistance Corrosion: |
Inside And Outside |
Transport Package: |
Brown Inner Box & Cardboard |
Filtration Grade: |
Medium Filter |
Color: |
Light Blue |
Connection: |
Rc1" |
Maxi. Operate Pressure: |
1.6mpa |
Efficiency: |
F9 |
Element Serve Life: |
4000~6000 Hours |
Configuration: |
Stainless Steel Manual Ball Valve |
Parallel Design: |
Yes |
Wall Connection Kit: |
Yes |
Filter Element: |
Top & Bottom Cap With Stainless Steel |
Flow Rate: |
2m³/Min |
Specification: |
Dimension: 90 X 82 X 286 Mm |
Model No.: |
HFD040 |
Origin: |
China |
HS Code: |
8421399090 |
Clapboard: |
Without Clapboard |
Filter Number: |
1 |
Medium Material: |
Fiberglass |
Type: |
Cartridge Filter |
Material: |
Aluminum Alloy |
Housing Serve Lige: |
15 Years |
Filtration Performance: |
From 5 μm To 0.01μm |
Operate Temperature: |
1.5~80ºc |
Resistance Corrosion: |
Inside And Outside |
Transport Package: |
Brown Inner Box & Cardboard |
Filtration Grade: |
Medium Filter |
Color: |
Light Blue |
Connection: |
Rc1" |
Maxi. Operate Pressure: |
1.6mpa |
Efficiency: |
F9 |
Element Serve Life: |
4000~6000 Hours |
Configuration: |
Stainless Steel Manual Ball Valve |
Parallel Design: |
Yes |
Wall Connection Kit: |
Yes |
Filter Element: |
Top & Bottom Cap With Stainless Steel |
Flow Rate: |
2m³/Min |
Specification: |
Dimension: 90 X 82 X 286 Mm |
Sources of compressed air pollutants:
1. Atmosphere
Air compressors suck in and compress a large amount of atmosphere. They continue to fill the system while bringing in extremely small pollutants. These pollutants include: water vapor, atmospheric dirt, dust and pollen particles, oil vapor, and microorganisms.
2. Air compressor
In addition to the pollutants inhaled from the atmosphere, the air compressor will also mix a small amount of oil into the compressed air flow during the air compression process. This oil may exist in the form of liquid oil, aerosols and oil vapor. It is also worth noting that although so-called oil-free compressors do not directly inject oil into the airflow, they still compress the same contaminated air like an air compressor, so any oil vapor in the surrounding environment will still be affected. It is compressed and enters the downstream system. After the compression stage, the aftercooler cools the air, which can condense any water vapor and mix it into the compressed air stream in the form of liquid water or aerosol.
Feature & Benefit
Operating pressure: 1.6Mpa
Flow rate: 1.0 to 7.2m³/min (till now)
Filtration Rate: 5μm/1μm/0.1μm/0.01μm
Material: Aluminum alloy
Unique lock design,to ensure easy for maintenance and air tightness.
Parallel and wall connection kit available.
High Efficiency Removal of Pollutant
Our Medium & high pressure filter features efficiency fiber glass and felt media to maximize the filtration of dry and wet dust, particulates, oil suspended solids and water droplets. Minimize pressured drop and maintain economical operation costs.
Superior Air Tightness
Unique lock design,easy to replace and maintenance
Avoid Second Pollution
Inside and outside with anti-corrosion, with stainless steel manual ball valve.
Low Differential Pressure
The optimized flow design and the use of filter materials serve to keep differential pressure at a constant low level during the entire service life of the element without compromising it's dirt holding capacity.
High-tech design
It is clearly visible due to the edges at the filter head of the compressed air inlet to ensure reliable connection between the left and right filter housings and the left and right filter housing parts during the assembly process.
Compressed air provides a smooth, non-turbulent air velocity when entering the Filter Element.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21℃),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21℃),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21℃),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21℃),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Product Specification
Model) | Pipe size | Flow rates | Dimension (mm) | ||||||
L/S | m³/min | scfm | W (Width) | D (Depth) | H (Height) | A | B | ||
HFD010 | RC1/2" | 16.7 | 1.0 | 35.3 | 90 | 82 | 255 | 37 | 179 |
HFD020 | RC3/4" | 25.0 | 1.5 | 53.0 | 90 | 82 | 255 | 37 | 179 |
HFD030 | RC3/4" | 30.0 | 1.8 | 63.6 | 90 | 82 | 286 | 37 | 212 |
HFD040 | RC1" | 33.3 | 2.0 | 70.6 | 90 | 82 | 286 | 37 | 212 |
HFD050 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 113 | 359 | 53 | 269 |
HFD060 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 113 | 359 | 53 | 269 |
HFD070 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 113 | 459 | 53 | 369 |
HFD080 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 113 | 459 | 53 | 369 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
YUKA service:
a. Providing professional consultation, technical support and special solutions