Why need Compressed Air Filter for compressed air whole system?
Air purification is essential for any air compressor for many reasons. Providing your pneumatic tools with clean air will extend their lifespan significantly.
When you use a compressor, every cubic foot of air that passes through contains millions of foreign particles, all of which can collect and damage or inhibit your tools. These particles include water droplets, oils, dirt, dust, bacteria and, potentially, pieces of heavy metals, such as lead, mercury and cadmium.
If the air passes through unfiltered, it can cause contamination of the control valves, swell the protective seals and cause premature wear, all potentially leading to equipment failure and increase repaired cost.
By implementing the proper filtration system for protection and purification, you can reduce machine downtime and overall cost, as well as limit the amount of necessary maintenance, repair and energy use. But you also need to maintain the filters for the best results, as clogged or worn filters can cause a significant pressure drop, making your compressor less effective.
YF Series Compressed Air Condensate Filter
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YF010 | RC1/2" | 16.7 | 1.0 | 35.3 | 96 | 79 | 261 | 29 | 198 | 118 |
YF020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 261 | 29 | 198 | 118 |
YF030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 295 | 29 | 233 | 153 |
YF040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 295 | 29 | 233 | 153 |
YF060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 403 | 37 | 296 | 208 |
YF070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 736 | 58 | 607 | 469 |
YF100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 736 | 58 | 607 | 469 |
YF110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
YF160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |