logo
Send Message
player background
live avator

5s
Total
0
Today
0
Total
0
Today
0
  • What would you like to know?
    Company Advantages Sample Service Certificates Logistics Service
Online Chat WhatsApp Inquiry
Auto
resolution switching...
Submission successful!

Hongrijia Depurate Facility Science & Technology Co., Ltd. yuka@szyuka.cn 86-0755-28686438

Hongrijia Depurate Facility Science & Technology Co., Ltd. Company Profile
products
Home > products > Compressed Air Dryer > High Efficiency Refrigerated or Desiccant Air Dryer

High Efficiency Refrigerated or Desiccant Air Dryer

Product Details

Place of Origin: China

Brand Name: Yuka

Payment & Shipping Terms

Minimum Order Quantity: 50pcs

Price: Negotiable

Packaging Details: Box Package

Delivery Time: 3-7working days

Payment Terms: L/C,T/T

Get Best Price
Product Details
Highlight:
Model NO.:
Hlx010
Cooling Way:
Air Cooling
Type:
Medium
Evaporator:
Aluminum
Power:
220v 50 Hz
Connection:
Rc3/4"
Dew Point:
Option Negative 20/40/70 ºc
Flow Rate:
1.2m³/Min
Air Compressor Brand:
Lg/Panasonic/Danfoss
Expansion:
Danfoss
With Dt Air Filter Inside:
Grade Pf/Ao/Aa/Ax
Filter Dryer:
Eco
Option Function:
Particle Detector
Input Power:
0.5kw
Color:
Red
Trademark:
Yuka
Transport Package:
Wooden Cardboard
Specification:
120x66x100cm
Origin:
China
HS Code:
8419399090
Flow:
Cross Flow
Material Status:
Solution
Drying Medium:
Air
Structure:
Enclosed
Operation Pressure:
Atmospheric Pressure
Inlet Temperature:
38~65ºc
Model NO.:
Hlx010
Cooling Way:
Air Cooling
Type:
Medium
Evaporator:
Aluminum
Power:
220v 50 Hz
Connection:
Rc3/4"
Dew Point:
Option Negative 20/40/70 ºc
Flow Rate:
1.2m³/Min
Air Compressor Brand:
Lg/Panasonic/Danfoss
Expansion:
Danfoss
With Dt Air Filter Inside:
Grade Pf/Ao/Aa/Ax
Filter Dryer:
Eco
Option Function:
Particle Detector
Input Power:
0.5kw
Color:
Red
Trademark:
Yuka
Transport Package:
Wooden Cardboard
Specification:
120x66x100cm
Origin:
China
HS Code:
8419399090
Flow:
Cross Flow
Material Status:
Solution
Drying Medium:
Air
Structure:
Enclosed
Operation Pressure:
Atmospheric Pressure
Inlet Temperature:
38~65ºc
Product Description
Product Description
High Efficiency Refrigerated Air Dryer & Desiccant Air Dryer
 
In today's industrial environments, it is important to ensure optimal equipment performance and product quality. To satisfy these stringent needs, advanced air drying technologies are essential. Our high efficiency refrigerated air dryer and desiccant air dryer offer great performance and reliability, providing your compressed air system with the necessary protection from moisture and contaminants. Our Desiccant Air Dryers creat efficient heat recovery systems to decrease energy consumption and improve all performance.

High Efficiency Refrigerated Air Dryer & Desiccant Air Dryer

High Efficiency Refrigerated Air Dryer & Desiccant Air Dryer


Space saving:
Integrated design of dryer, filter, gas-water separator and suction dryer, saving space;

Energy saving:
The design of three-in-one aluminum alloy heat exchanger minimizes the process loss of cooling capacity and improves the recycling of cooling capacity. Under the same processing capacity, the total red and green input of the modified model will be reduced by 15-30

High efficiency:
The integrated heat exchanger is equipped with diversion fins, which is the uniform heat exchange of compressed air inside, and the built-in gas-water separation device is equipped with a Stainless Steel Filter screen to separate the moisture more thoroughly.
Intelligent: Multi-channel temperature and pressure monitoring, real-time display of dew point temperature, automatic recording of accumulated running time, self-diagnosis function, display of corresponding alarm codes, and automatic protection of equipment.


Environmental protection:
Corresponding to the international Montreal agreement, this series of models all use R134a, R410a, R407c environmentally friendly refrigerants, and the degree of damage to the atmosphere is zero, adapting to international market needs;

Stability:
Standard configuration constant pressure expansion valve, standard configuration intelligent temperature control, laboratory test when the temperature reaches 65 ºC, ambient temperature reaches 42 ºC, flammable and stable operation, at the same time with temperature and pressure dual anti-freeze protection When the time is low, the output of the compressor is automatically stopped, and the aluminum plate is used to exchange the stored cooling capacity to provide heat exchange and energy saving, while extending the service life of the equipment.

 
 
 
HL020- (1)37.Comvac Asia 2023 (61)Secador de refrigeração a ar